Item Coversheet

6.B.


Shakopee Planning Commission Meeting
August 5, 2021


FROM: Kyle Sobota, Senior Planner 
TO:Planning Commission
Subject:
PUBLIC HEARING: Planned Unit Development Amendment to Southbridge Crossings East PUD
Policy/Action Requested:
Recommend City Council approval of the proposed PUD Amendment.
Recommendation:

Recommend approval of the resolution, as presented.

Discussion:

Site Information:

Address: 8350 Hansen Avenue

Applicant: Stephanie Schultz

Property Owner: McDonald's USA LLC

Lot Area: 1.31 Acres

Current Zoning: B-1, Highway Business

2040 Comp. Plan: Mixed Use Center

 

Stephanie Schultz of Tarr Group, representing WMG Development has applied for a PUD Amendment to the Southbridge Crossings East PUD to allow for construction of a 4,200 square-foot freestanding dental office at 8350 Hansen Avenue (see attached location map / plans).

 

The surrounding uses in the Southbridge Crossings East PUD are Caribou Coffee / Einstein Brothers Bagels, Marcus Theatres, McCoy's Copper Pint and Home Depot. All of the surrounding parcels are zoned B-1, Highway Business. Dental offices are a permitted use in the B-1 district. 

 

This site was platted for the development of a McDonald's restaurant in 2013. McDonald's received a Building Permit approval, but never started construction. The applicant is proposing to use the two existing driveway accesses from the main north-south private drive that were constructed for McDonald's.

 

The applicant requested concessions to the parking maximums in City Code in their narrative. The City Code for parking maximums actually only apply to sites where at least 30 parking spaces are required. The minimum parking requirement in City Code for a dentist office of this size is 19 parking spaces, so a concession is not required.

 

The applicant has submitted proposed building elevations with this request. As proposed, the building does not meet the materials standards requirements in City Code. The applicant is proposing Dryvit / Synthetic stucco as a major material. City Code does not permit synthetic stucco below 12' in height because of the ability for the material to be easily damaged. The amount of window coverage on the elevation with the main entrance is slightly below the amount required by City Code, a condition has been added to the draft resolution to meet City Code requirements.

 

Staff is also recommending a sidewalk connection to the existing sidewalk near the northeast corner of the Caribou Coffee building. Sidewalk connections to different uses are requirement in the PUD ordinance.

 

Staff recommends approval of the request, with minor changes to the proposed plans.

 

 

 

 

 

 

ATTACHMENTS:
Description
Location Map
Applicant Narrative
Building Elevations 1
Building Elevations 2
Building Elevations 3
Civil Plans
Landscape Plan
Floor Plan
Draft Resolution